Setup Guide

Brocade Fabric OS Message Reference 603
53-1004119-01
RPCD-1001
5
RPCD Messages
RPCD-1001
Message Authentication Error: client \"<IP address>\" has bad credentials: <bad user name
and password pair>.
Message Type LOG
Severity WARNING
Probable Cause Indicates an authentication error was reported. The specified client IP address has faulty credentials.
Recommended
Action
Enter the correct user name and password from the Fabric Access API host.
RPCD-1002
Message Missing certificate file. Secure RPCd is disabled.
Message Type LOG
Severity WARNING
Probable Cause Indicates a Secure Sockets Layer (SSL) certificate is missing.
Recommended
Action
To enable remote procedure call daemon (RPCD) in secure mode, install a valid SSL certificate on the
switch.
RPCD-1003
Message Permission denied accessing certificate file. Secure RPCd is disabled.
Message Type LOG
Severity WARNING
Probable Cause Indicates the Secure Sockets Layer (SSL) certificate file configured on the switch could not be accessed
because root did not have read-level access.
Recommended
Action
Change the file system access level for the certificate file to have root read-level access.