Setup Guide

Brocade Fabric OS Message Reference 607
53-1004119-01
RTWR-1001
5
RTWR Messages
RTWR-1001
Message RTWR <routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail 3>, 0x<detail
4>, 0x<detail 5>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that an error occurred in Reliable Transport With Response (RTWR) due to one of the following
reasons:
The system ran out of memory.
The domain may be unreachable
The frame transmission failed.
An internal error or failure occurred.
The message contains the name of the routine that has an error and other error-specific information.
Refer to values in details 1 through 5 for more information.
Recommended
Action
Restart the switch.
RTWR-1002
Message RTWR <error message: maximum retries exhausted> 0x<port>, 0x<domain ID>, 0x<retry
count>, 0x<status>, 0x<process ID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that Reliable Transport With Response (RTWR) has exhausted the maximum number of retries
for sending data to the specified domain.
Recommended
Action
Execute the fabricShow command to verify that the specified domain ID is online.
If the switch with the specified domain ID is offline, enable the switch using the switchEnable command.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.