Setup Guide

638 Brocade Fabric OS Message Reference
53-1004119-01
SEC-1106
5
SEC-1106
Message Failed to sign message data.
Message Type LOG
Severity ERROR
Probable Cause Indicates that some public key infrastructure (PKI) objects on the switch are not in a valid state, and a
signature operation failed.
Recommended
Action
Run the secCertUtil show -fcapall command and verify that all PKI objects exist on the switch. If a
failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Fabric
OS Administrator's Guide.
SEC-1107
Message Stamp is 0.
Message Type LOG
Severity INFO
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1108
Message Fail to reset stamp on all switches.
Message Type LOG
Severity ERROR
Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required
resources to perform the operation or because it failed to send the message to all switches in the fabric.
Recommended
Action
Verify that the security event was planned. If the security event was planned, run the secFabricShow
command to verify that all switches in the fabric are in the ready state. When all switches are in the ready
state, retry the operation.