Setup Guide

732 Brocade Fabric OS Message Reference
53-1004119-01
SSMD-1216
5
SSMD-1216
Message QoS failed programming interface 0x<Interface ID> Pause.
Message Type LOG
Severity WARNING
Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface Pause feature.
Recommended
Action
Delete and reapply the QoS Pause policy.
If the message persists, restart or power cycle the switch.
SSMD-1217
Message QoS CEE could not comply with FCoE scheduler policy for CEE Map <CEE Map name>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that DCE SSM was unable to translate the CEE Map and Fibre Channel over Ethernet (FCoE)
configuration into an ETS scheduler policy implementable by the dataplane ASIC.
Recommended
Action
Redefine CEE Map and FCoE into a configuration that translates into an ETS scheduler policy requiring
eight or fewer traffic classes.
SSMD-1300
Message CEE Map <ceemap> is created with precedence <precedence>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified CEE Map has been created.
Recommended
Action
No action is required.