Setup Guide

.
TABLE 12 SSL messages and actions
Message Action
The page cannot be displayed The SSL certificate is not installed correctly or HTTPS is not enabled
correctly. Make sure that the certificate has not expired, that HTTPS is
enabled, and that certificate file names are configured correctly.
The security certificate was issued by a company you have not chosen to
trust.
The certificate is not installed in the browser. Install it as described in the
Fabric OS Administrator's Guide
.
The security certificate has expired or is not yet valid Either the certificate file is corrupted or it needs to be updated. Click View
Certificate to verify the certificate content. If it is corrupted or out of date,
obtain and install a new certificate.
The name on the security certificate is invalid or does not match the name
of the site file
The certificate is not installed correctly in the Java Plug-in. Install it as
described in the
Fabric OS Administrator's Guide
.
This page contains both secure and nonsecure items. Do you want to
display the nonsecure items?
Click No in this pop-up window. The session opens with a closed lock
icon on the lower-right corner of the browser, indicating an encrypted
connection.
Gathering additional information
For security-related issues, use the following guidelines to gather additional data for your switch support provider.
Use the supportSave -n command.
If not sure about the problem area, use the supportSave -n to collect data from all switches in the fabric.
If you think it may be related to E_Port authentication, use the supportSave -n command to collect data from both switches of
the affected E_Port.
If you think this is a policy-related issue, FCS switch, or other security server-related issue, then use supportSave -n to collect
data from the Primary FCS switch and all affected switches.
If login-related, then also include the following information:
Does login problem appear on a Serial, CP IP, or Switch IP address connection?
Is it CP0 or CP1?
Is the CP in active or standby?
Is it the first time login after firmwareDownload and reboot?
SNMP
This section describes symptoms with associated causes and recommended actions for SNMP-related issues.
Symptom SNMP management station server is unable to receive traps from fabric.
Probable cause and recommended action There are several causes related to this generic issue. You must verify the
following:
There are no port filters in the firewalls between the fabric and
the SNMP management station.
If your SNMP management station is a dual-homed server,
check that the routing tables are set up correctly for your
network.
Security
Brocade Fabric OS Troubleshooting and Diagnostics Guide
53-1004126-01 65