To display the Brocade model name for each blade on a Brocade X6-8:
switch:user> slotshow -m
Slot Blade Type ID Status
-------------------------------------------------
1 CP BLADE 175 CPX6 ENABLED
2 CP BLADE 175 CPX6 ENABLED
3 AP BLADE 186 SX6 ENABLED
4 AP BLADE 186 SX6 ENABLED
5 SW BLADE 178 FC32-48 ENABLED
6 SW BLADE 178 FC32-48 ENABLED
7 CORE BLADE 177 CR32-8 ENABLED
8 CORE BLADE 177 CR32-8 ENABLED
9 AP BLADE 186 SX6 ENABLED
10 SW BLADE 178 FC32-48 ENABLED
11 SW BLADE 178 FC32-48 ENABLED
12 AP BLADE 186 SX6 ENABLED
To display power consumption information on a Brocade X6-8:
switch:user> slotshow -p
Slot Blade Type ID DC Power Status
Consumption
-------------------------------------------------
1 CP BLADE 175 55 ENABLED
2 CP BLADE 175 55 ENABLED
3 UNKNOWN - VACANT
4 AP BLADE 186 425 INSERTED, NOT POWERED ON
5 UNKNOWN - VACANT
6 SW BLADE 178 260 ENABLED
7 CORE BLADE 177 450 ENABLED
8 CORE BLADE 177 450 ENABLED
9 UNKNOWN - VACANT
10 UNKNOWN - VACANT
11 SW BLADE 178 260 INSERTED, NOT POWERED ON
12 UNKNOWN - VACANT
Total DC Power Consumption:
2184 watts
Total AC Power Consumption:
2426 watts AC @ 90% efficiency (8280 BTU)
Power Efficiency:
3.73 watts per port, 0.58 watts per Gb
INSERTED, NOT POWERED ON blades are not included in Total Power Consumption.
To display the Brocade model name for each blade on a Brocade X6-4:
switch:user> slotshow -m
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 CP BLADE 175 CPX6 ENABLED
2 CP BLADE 175 CPX6 ENABLED
3 SW BLADE 178 FC32-48 ENABLED
4 SW BLADE 178 FC32-48 ENABLED