Reference Guide

1082 Brocade Fabric OS Command Reference
53-1004112-02
switchShow
No_Light
The module is not receiving light. This state is not applicable to 16 Gbps-capable
interchassis link (ICL) ports.
No_SigDet
No signal is detected on the port. For 16 Gbps-capable interchassis link (ICL) ports, this
state replaces the No_Light indicator. It indicates that a quad small form-factor pluggable
(QSFP) has been installed but is not connected with a cable.
No_Sync
The module is receiving light but is out of sync.
In_Sync
The module is receiving light and in sync.
Laser_Flt
The module is signaling a laser fault.
Port_Flt
The port is marked faulty.
Diag_Flt
The port failed diagnostics.
Lock_Ref
The port is locking to the reference signal.
Testing
The port is running diagnostics.
Offline
A port connection is not established (for virtual ports only).
Online
The port is up and running.
Transient
The port is disabled and re-enabled by MAPS to recover from the bottleneck condition
caused by the target device.
Proto
Protocol support by GbE port. Valid protocols include the following:
ISCSI
The port supports ISCSI (deprecated).
FCIP
The port supports FCIP.
FCoE
The port supports Fibre Channel over Ethernet.
LAN
The port supports LAN.