Reference Guide

Brocade Fabric OS Command Reference 117
53-1004112-02
chassisShow
chassisShow
Displays all field replaceable units (FRUs).
Synopsis chassisshow
Description Use this command to display the Field Replaceable Unit (FR) header content for each object in the chassis and
chassis backplane version. This command displays the following information:
1. The chassis family, for example, DCX 8510.
2. The backplane version number, in hexadecimal: Chassis Backplane Revision: xx
3. The first line of each record contains the object ID. If the FRU is part of an assembly, a brief description is
displayed in parentheses.
a. Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor),
WWN (world wide name), or UNKNOWN.
b. Object number: Slot nn (for blades), Unit nn (for everything else).
4. FRU header version number: Header Version: x
5. Displays the maximum allowed power consumption for a given hardware component: positive for power
supplies and negative for power consumers. The combined total maximum allowed power consumption for
the entire chassis is shown in the output of the slotShow -p command. Power Consume Factor: -xxx
6. Displays the real-time power consumption for each FRU that supports real-time power measurement. Only
16Gb blades currently support real time measurement of power being consumed by these blades. When the
capability is not supported for a FRU, the line is suppressed. Power Usage (Watts):
7. Factory part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx
8. Factory serial number (up to 12 characters): Factory Serial Num:xxxxxxxxxx
9. FRU manufacture date: Manufacture: Day: dd Month: mm Year: yyyy
10. Date of the last FRU header update: Update: Day: dd Month: mm Year: yyyy
11. Cumulative number of days the FRU has been powered on: Time Alive: dddd days
12. Time elapsed, in days, since the FRU was last powered on: Time Awake: dddd days
13. Externally supplied ID (up to 10 characters): ID: xxxxxxxxxx
14. Externally supplied part number (up to 20 characters): Part Num: xxxxxxxxxxxxxxxxxxxx
15. Externally supplied serial number (up to 20 characters): Serial Num: xxxxxxxxxxxxxxxxxxx
16. Externally supplied revision number (up to 4 characters): Revision Num: xxxx
The output of this command depends on the platforms on which it is executed. On some platforms, for certain
FRU types, a few items may not be available. In these cases, the lines are suppressed. Possibly affected lines are 1,
3 through 7, 9, and 11 through 14. In addition, for lines 11 through 14, if there is no data set, these lines are
suppressed.