Reference Guide

172 Brocade Fabric OS Command Reference
53-1004112-02
diagClearError
diagClearError
Clears the diagnostics failure status.
Synopsis diagclearerror [[--slot] slot] -all
Description Use this command to clear the diagnostics failure status. When used without operands, this command clears all
port failure flags.
Notes The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric
OS Commands" and "Command Availability" for details.
Operands This command has the following operand:
--slot slot
Specify the slot on which to clear the diagnostics failure status. The default is set to 0 and
designed to operate on fixed-port-count products.
-all
If specified, all blades clear.
Examples To clear the diag software flag:
switch:admin> diagclearerror --slot 8
ERROR: DIAG CLEARERR
Diagnostics Errors Cleared, port: 8/31
Err# 0120041 081F
SEE ALSO None