Reference Guide

174 Brocade Fabric OS Command Reference
53-1004112-02
diagEnablePost
diagEnablePost
Enables the power-on self-test (POST).
Synopsis diagenablepost
Description Use this command to enable POST. A reboot is not required for this command to take effect. POST includes two
phases: POST Phase I mainly tests hardware and POST Phase II tests system functionality.
Use the diagPost command to display the current POST status, and use diagDisablePost to disable POST.
Notes The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric
OS Commands" and "Command Availability" for details.
Operands None
Examples To enable POST:
switch:admin> diagenablepost
Config update Succeeded
Diagnostic POST is now enabled.
SEE ALSO diagDisablePost, diagPost