Reference Guide

Brocade Fabric OS Command Reference xxi
53-1004112-02
What is new in this document
extnCfg - Added the --config -default and --config -clear operands.
fanDisable - Added note that the fan units on a Brocade X6 Director do not change their RPM speed to 0 and they take few
minutes to change the speed to minimum RPM after being disabled.
faPwwn - Added a note that the ports must be disabled before executing the --enable and --assign options.
fcipLedTest - Added the behavior of this command on the Brocade SX6 extension blade.
fcipPathTest - Added details for Brocade SX6 extension blade.
fcrEdgeShow - This command displays information only for online EX_Ports.
fddCfg - Added a note that when a policy is set to strict mode, the manual distribution of the policy is not allowed.
firmwareDownload - Removed the following unsupported operands: -a, -t, -e, and -o.
flow - Added the predefined frame type ‘Srr’.
fosExec - Added a note that the --domain operand can be executed only if the remote Fosexec feature is enabled on local and
remote switches.
haShow - Added slot number details for the Brocade X6 Director. Added haShow command example on the Brocade X6
Director.
mapsConfig - Removed sw_critical and sw_marginal MAPS actions. These actions are always enabled by default.
mapsDb - Added new fields ‘fenced circuits’ and ‘ports with highest zoned device ratio’ fields.
mapsRule - Added the following monitoring systems under the respective category”
GE Port Health: GE_CRC, GE_INV_LEN, GE_LOS_OF_SIG, STATE_CHG, UTIL, and IP_UTIL.
FCIP health: IP_UTIL, IP_PKTLOSS, IP_RTT, and IP_JITTER.
Fabric performance impact: CRED_ZERO, THPUT_DEGRADE, and IT_FLOW.
Security health: DAYS_TO_EXPIRE, EXPIRED_CERTS, DID_CHG, FLOGI, and FAB_CFG.
Fabric state change: TEMP, ETH_MGMT_PORT_STATE, and FLASH_USAGE.
Switch status policy: FAN_AIRFLOW_MISMATCH.
msConfigure - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlClearDB - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlMgmtActivate - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlMgmtDeactivate - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msTdDisable - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msTdEnable - Removed the following note: This command is supported only in AD0 and AD255 contexts.
nodeFind - The command is enhanced to accept WWN as single hexadecimal value.
nsShow - Added the ‘Device link speed’ field.
passwdCfg - Added the -charset, -allowuser, --hash, and --showhash options.
portCfg - Added details for Brocade SX6 blade and removed all references to Brocade 7800. Added the following options: sla,
--proto-app, --rst-propagation, --non-terminated, and --load-leveling. Removed the --legacy option.
portCfgCompress - Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are
supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported.
portCfgDefault - Added the --help option.
portCfgEncrypt - Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are
supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported.