Reference Guide
322 Brocade Fabric OS Command Reference
53-1004112-02
ficonShow
Byte BB 0x0a
Switch
Byte CC 0x00
Port number. It is dynamically assigned whenever a link incident occurs.
Parm
Displays the incident node parameters type in three bytes, 0xAABBCC:
Byte AA
Possible values include the following:
0x00
Reserved.
0x20
FC-SB-2 and updates.
0x40
Other FC-4s including FCP and updates.
0x60
FC-SB-2 and updates and other FC-4s including FCP and updates.
0x80
FC-4 support not specified.
0xa0
Reserved.
0xc0
Reserved.
0xe0
Vendor-specific.
Byte BB
Possible values include the following:
0x00
Unspecified class.
0x01
Direct access storage device, if it is a storage port; otherwise, not channel-to-channel
capable.
0x02
Magnetic tape, if it is a storage port; otherwise, a reserved field for a channel port.
0x03
Input unit record, if it is a storage port; otherwise, a reserved field for a channel port.
0x04
Output unit, if it is a storage port; otherwise, a reserved field for a channel port.
0x05
Reserved field for a channel port.