Reference Guide

362 Brocade Fabric OS Command Reference
53-1004112-02
flow
-srcdev device_id
Specifies the 3-byte source ID of the originator device. The device_id can be in PID or
PWWN format depending on the device ID mode configured using the -deviceIdMode
operand. The PID format is 0xDDAAPP, where DD is the Domain ID, AA is the Area ID and
PP is the AL_PA ID. The PWWN format is "XX:XX:XX:XX:XX:XX:XX:XX". Specify "*" to
enumerate all originator devices.
-dstdev device_id
Specifies the 3-byte destination ID of the destination device. The device_id can be in PID or
PWWN format depending on the device ID mode configured using the -deviceIdMode
operand. The PID format is 0xDDAAPP, where DD is the Domain ID, AA is the Area ID and
PP is the AL_PA ID. The PWWN format is "XX:XX:XX:XX:XX:XX:XX:XX". Specify "*" to
enumerate all destination devices.
-lun LUN_id
Specifies the LUN identification in decimal or hexadecimal (2-byte value) format. The valid
range for LUN_id is from 0 through 65535 (0x0000 to 0xFFFF). The LUN ID includes the
addressing mode. If the most significant byte (MSB) is not specified, 0x00 is used. This
operand is not supported by the Flow Generator feature.
-frametype type
Specifies the predefined frame type. Valid values for type include the following: SCSI,
SCSIRead, SCSIWrite, SCSIRW, SCSI2Reserve, SCSI3Reserve, scsicmdsts, ABTS,
BAACC, SCSI2Release, SCSI3Release, SCSITur, SCSI2ReserveRelease,
SCSI3ReserveRelease, SCSIGoodStatus, SCSICheckStatus, SCSIResvConflict,
SCSIInquiry, SCSIXferrdy, Srr, and BARJT. This operand is not supported by the Flow
Generator feature.
-count value
Specifies the number of times the output must be repeated. The default value is 1 and the
maximum value is 10.
-time time_interval
Displays the flow information for the specified time interval until it is terminated with Ctrl + C.
Values are in seconds. The time interval must be specified in multiples of 5, for example, 5,
10, 15, or 20 seconds.
-verbose
Displays the flow or feature statistics in verbose mode.
-domain domain_id
Displays detailed information for the specified domain. The operand is valid only with the
fabInfo feature.
-sortby field
Displays the sub-flows for a feature in the specified order. The field can be columnX, where
X is the column number. The value of X
can be from 1 to maximum number of columns
present in the --show output. For the Flow Mirror feature, the sub-flows may or may not be
present but the mirrored frames can be sorted. The -sortby option can be applied if only
one feature is specified with the --show command.
-ctrlcfg
Displays the control parameters.