Reference Guide
382 Brocade Fabric OS Command Reference
53-1004112-02
frameLog
-type timeout | du | unroute
Specifies the discard frame types to enable. Specify timeout for timeout discard frames, du
for destination unreachable frames, and unroute for unroutable frames.
--clear
Clears the stored history of discarded frames. This operation is permitted only when the
feature is enabled.
--status
Displays the current status of the frame log service, and the type of discard frames that are
being logged.
--show
Prints a listing of details about stored frames that match the specified filter criteria. This
operation is permitted only when the feature is enabled. You can specify one or more of the
following options to filter the output. When used without operands, the --show command
displays the unfiltered output. This option supports specifying that the TX port or RX port of
displayed frames should be a backend port.
-type timeout | du | unroute
Specifies the discard frame types to display. Specify timeout for timeout discard frames, du
for destination unreachable frames, and unroute for unroutable frames.
-txport [slot/]port
Displays only the frames that were bound to exit by the specified egress port. The -txport
option accepts argument "-1" (for fixed-port switches) or "-1/-1" (for modular switches).
These stand for "any backend port". Using this notation, you can select specifically those
discarded frames that have a backend port in the TX port field. Individual backend ports
cannot be specified, only the quality of being a backend port can be specified.
-rxport [slot/]port
Displays only the frames that entered the chassis on the specified port. The -rxport option
accepts argument "-1" (for fixed-port switches) or "-1/-1" (for modular switches). These stand
for "any backend port". Using this notation, you can select specifically those discarded
frames that have a backend port in the RX port field. Individual backend ports cannot be
specified, only the quality of being a backend port can be specified.
-sid source_PID
Displays only the frames with the specified 24-bit source address in the FC header. The
port ID (PID) must be written in hexadecimal and must be prefixed by 0x.
-did destination_PID
Displays only the frames with the specified 24-bit destination address in the FC header.
The port ID (PID) must be written in hexadecimal and must be prefixed by 0x.
-sfid fabric_ID
Displays only the frames with the specified fabric ID as the source fabric ID.
-sdfid fabric_ID
Displays only the frames with the specified fabric ID as the destination fabric ID.