Reference Guide
526 Brocade Fabric OS Command Reference
53-1004112-02
mapsRule
Backend Port Health
Monitors backend port statistics. Valid values for the port health category include the
following:
CRC
Cyclic redundancy check errors
ITW
Invalid transmit words
LR
Link reset
BAD_OS
Invalid ordered set
FRAME_TRUNC
The frame is too short (less than 36 bytes).
FRAME_LONG
The frame is longer than expected (greater than 2148 bytes).
GE Port Health
Monitors backend port statistics. Valid values for the port health category include the
following:
GE_CRC
Cyclic redundancy check errors
GE_INV_LEN
Invalid length
GE_LOS_OF_SIG
Loss of signal
STATE_CHG
Tunnel state change
UTIL
Tunnel FC throughput
IP_UTIL
Tunnel IP throughput
FRU health
Monitors the field-replaceable units, including ports, power supplies, and flash memory.
Valid values for the FRU health category include the following:
PS_STATE
Power supply state has changed
FAN_STATE
Fan state has changed
BLADE_STATE
Blade state has changed