Reference Guide
620 Brocade Fabric OS Command Reference
53-1004112-02
portCfg
mirrorport
Configures a mirror port on the local port. The port mirroring feature reroutes data frames
between two devices to the mirror port. Port mirroring can aid in troubleshooting common
FC end-to-end communication problems. The command prompts for confirmation that the
specified port be enabled as a mirror port. Once a port is configured as a mirror port, the
port can only be used as part of a mirror connection. Port Mirroring is not supported over
FCIP links (VE tunnels). The port mirroring feature is not supported on the Gen6 platforms.
The syntax for portCfg mirrorport is as follows:
portcfg mirrorport [slot/]port mode
Valid modes for mirrorport include the following:
--disable
Disables the configuration. When disabled, a port cannot be a mirror port.
--enable
Enables the configuration. When the mirror port feature is enabled to a port, a mirror
connection can use this port to mirror traffic.
Examples To enable a mirror port configuration:
switch:admin> portcfg mirrorport 2/4 --enable
Please confirm enable of Mirror Port (Y,y,N,n):[n] y
To configure a range of ports as RSCN-suppressed:
switch:admin> portcfg rscnsupr 2/4-7 --enable
Function Configure extension-related parameters on the Brocade 7840 switch, and Brocade FX8-24 and Brocade SX6
blades.
Synopsis portcfg action [slot/] ge_port | name arguments