Reference Guide

730 Brocade Fabric OS Command Reference
53-1004112-02
portCfgShow
Encryption
Displays ON when encryption is enabled on a port. Displays (..) or OFF when the
configuration is disabled. Encryption is enabled by the portCfgEncrypt command; it is
disabled by default.
10G/16G FEC
Displays ON when Forward Error Correction (FEC) is enabled on a port and the port is
online. Displays (..) or OFF when the configuration is disabled. FEC is enabled by the
portCfgFec command; it is enabled by default.
16G FEC via TTS
Displays ON when control of the Forward Error Correction (FEC) state is permitted via TTS
by an externally attached host or device. Displays (..) or OFF when the external control of
FEC is disabled. Refer to the portCfgFec command for additional information.
When portCfgShow is issued for a single FCoE port, only the following fields are displayed: Area Number, Speed
Level, AL_PA Offset, RSCN Suppressed, and NPIV PP Limit. If the command is issued without operands on a
DCX with one or more FCOE10-24 blades, the port parameters that are not valid on the FCoE ports are marked
with a dash (-). Refer to the example section for an illustration.
You can identify a single port to be displayed by its port number or by its port index number. Port ranges are
supported with index numbers or by specifying a slot or a slot range. Use switchShow for a listing of valid ports,
slots, and port index numbers. When used without operands, this command displays all persistently disabled ports
on the switch.
Specifying multiple ports with the index (-i) or slot (-s) option is supported only if PortSwap is disabled. They are
not supported on GbE ports and configured F_Port trunks. Use the -i option without a port index argument to
display the portSwap status, or alternately use portSwapShow.
Notes The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric
OS Commands" and "Command Availability" for details.
The Fabric OS port configuration commands are not supported on FCoE ports.
Operands This command has the following operands:
slot
For bladed systems only, specifies the slot number of the port to be configured, followed by
a slash (/).
port
Specifies the number of the port to be displayed, relative to its slot for bladed systems. Use
switchShow for a listing of valid port numbers.
-i index1[-index2]
Specifies a port or a range of ports identified by port index numbers. You can specify
multiple index ranges separated by a space, for example, -i 33-38 40-60.
-f
Ignores nonexisting ports. This operand is valid only with the -i option.
-slot slot1[-slot2]
Specifies a slot or a range of slots. You can specify multiple slot ranges separated by a
space, for example,-s 1-3 5-7.