Reference Guide
768 Brocade Fabric OS Command Reference
53-1004112-02
portDPortTest
Remote port index
The port number on the remote side of the link
Mode
The testing mode: Automatic (initiated due to port online event) or Manual (manually
restarted using this command).
No. of test frames
Number of frames sent for link traffic test.
Test frame size
The test frame size in bytes.
Pattern
The predefined pattern name.
Payload
The user-defined payload pattern.
FEC (enabled/option/active)
The forward error correction (FEC) status. This option is not supported for D_Port HBA.
CR (enabled/option/active)
The credit recovery (CR) status. This option is not supported for D_Port HBA.
Start time
Date and time of test start
End time
Date and time of test completion
Status
On the link initiator, this field displays the overall test status as PASSED, FAILED, SKIPPED,
IN PROGRESS, NOT STARTED, or STOPPED. On the link responder, the status displays
PASSED, FAILED, STOPPED, or RESPONDER.
Test
For each sub-test, the command displays the Start time, test result (PASSED, FAILED, IN
PROGRESS, NOT STARTED, STOPPED, or RESPONDER), estimated time in seconds,
and diagnostic comments. Comments include the following:
No SFP or chip support
The test result is skipped because the SFP or port is not capable of D_Port functionality.
See remote port results
The test result related to this comment is RESPONDER. The port is in responder state and
test results will be available at the initiator port on the remote side of the link.
Remote port is not ready to start the test
The test failed because the remote port is not ready to start the D_Port test.
No remote SFP or chip support
The test is skipped because the D_Port test is run between a QSFP and SFP port
connected through break-out cable or when the remote SFP is not capable of running the
optical loopback test.