Reference Guide

Brocade Fabric OS Command Reference 783
53-1004112-02
portFlagsShow
portFlagsShow
Displays the port status bitmaps for all ports in a switch.
Synopsis portflagsshow
Description Use this command to display the following status for a port:
SNMP
Displays whether the port is online or offline.
Physical
Displays the port physical status. Valid values are In_Sync, No_Light (8 Gbps-capable ports
only), and No_SigDet (quad small form-factor pluggables (QSFPs) installed without cables).
Refer to switchShow help for more information on these states.
Flags
Displays whether there is an SFP inserted in the port, whether the port is active, and the port
type.
Notes The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric
OS Commands" and "Command Availability" for details.
Operands None
Examples To display the port status for all ports in the switch:
switch:user> portflagsshow
Port SNMP Physical Flags
-------------------------------
0 Online In_Sync PRESENT ACTIVE F_PORT G_PORT \
U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI
1 Online In_Sync PRESENT ACTIVE E_PORT G_PORT \
U_PORT SEGMENTED CBL_LB LOGIN LED
2 Offline No_Module PRESENT U_PORT LED
3 Offline No_Light PRESENT U_PORT LED
4 Offline No_Module PRESENT U_PORT LED
5 Offline No_Module PRESENT U_PORT LED
6 Offline No_Module PRESENT U_PORT LED
7 Offline No_Module PRESENT U_PORT LED
8 Offline No_Module PRESENT U_PORT LED
9 Offline No_Module PRESENT U_PORT LED
10 Online In_Sync PRESENT ACTIVE F_PORT G_PORT \
U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI
11 Offline No_Module PRESENT U_PORT LED
12 Offline No_Module PRESENT U_PORT LED
13 Offline No_Module PRESENT U_PORT LED
14 Offline No_Module PRESENT U_PORT LED
15 Offline No_Module PRESENT U_PORT LED
16 Online In_Sync PRESENT ACTIVE F_PORT G_PORT \
U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI
17 Online In_Sync PRESENT ACTIVE F_PORT G_PORT \
U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI
18 Offline No_Module PRESENT U_PORT LED