Reference Guide
Brocade Fabric OS Command Reference 803
53-1004112-02
portLogShow
Args
Displays additional information about the event as follows:
start
Start type: 0 = enable ports, 100 = disable ports.
disable
State (refer to state codes).
enable
Mode: 0 normal; nonzero loopback.
Tx & Rx
Header words 0,1,4 (R_CTL,D_ID,S_ID,OX_ID,RX_ID) and the first payload word.
reject
FC-PH reject reason.
busy
FC-PH busy reason.
ctin
Argument 0 is divided into two 16-bit fields: [A] A bit map indicating whether subsequent
arguments are valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are
valid). [B] The CT-based service command code.
Argument 1 is the first word of the CT payload, if applicable (as specified in [A]). Argument 2
is the second word of the CT payload, if applicable (as specified in [A]).
ctout
Argument 0 is also divided into two 16-bit fields: [A] a bit map indicating whether
subsequent arguments are valid (0001 means argument 1 is valid, 0003 means arguments
1 and 2 are valid). [B] the CT command code indicating whether an accept (8002) or a reject
(8001). If [B] is an accept, argument 1 and 2 represents the first and second words of the CT
payload, if applicable (as specified in [A]). If [B] is a reject, argument 1 contains the CT reject
reason and explanation code.
errlog
Error type (refer to errShow).
loopscn
The meaning further depends on each loop state:
OLP
Offline reason code, usually zero.
LIP
Reason code for LIPs initiated by FL_Port, if the code value is 800x (x = [1,0xc], see below),
or the lower two bytes of the LIP received, if the code value is other than 800x.
LIM
Usually zero.
BMP
Memory address for the loop bitmap.