Reference Guide
Brocade Fabric OS Command Reference 813
53-1004112-02
portLoopbackTest
-uports itemlist
Specifies a list of user ports to test. If this operand is omitted, by default the test will run on
all valid blade ports in the slot. Refer to itemList for more information on the itemlist
parameter. This option is only available for 16 Gbps-capable and 32 Gbps-capable blades.
Diagnostics When it detects failures, the test may report one or more of the following error messages. If errors persist, contact
Technical Support.
DATA
Data received does not match the data sent.
ERRSTAT
Errors were found in the ASIC statistics.
INIT
Port failed to initialize.
PORTDIED
A previously initialized port went to an uninitialized state.
STATS
Errors were found in the ASIC statistics.
TIMEOUT
Did not receive a frame in the given timeout period.
XMIT
Frame transmission failure.
Examples To run a functional test in default mode:
switch:admin> portloopbacktest
Running portloopbacktest ..............
PASSED.
SEE ALSO itemList