Reference Guide

832 Brocade Fabric OS Command Reference
53-1004112-02
portShow
Overrun
Buffer overrun interrupts.
Suspended
Transmission suspended interrupts.
Parity_err
Central memory parity errors.
2_parity_err
Secondary transmission parity errors.
CMI_bus_err
Control message interface errors.
FEC Corrected Blocks
FEC corrected block errors.
FEC Uncorrected Blocks
FEC uncorrected block errors.
The second column displays link error status block counters.
The third column shows the number of F_RJTs and F_BSYs generated. For L_Ports, the third column also
displays the number of loop initialization protocols (LIPs) received, number of LIPs transmitted, and the last LIP
received.
Operands This command has the following port operands:
slot
For bladed systems only, specifies the slot number of the port to be displayed, followed by
a slash (/).
port
Specifies the number of the port to be displayed, relative to its slot for bladed systems. Use
switchShow for a listing of valid port numbers.
-link [-force]
Displays the diagnostic information from cached data for a local switch port and the peer
port. The -force option displays the real-time diagnostic information from the registers for a
port.
-i index1[-index2]
Specifies a port or a range of ports identified by port index numbers. You can specify
multiple index ranges separated by a space, for example, 33-38 40-60. Port indexes are
supported only if PortSwap is disabled. They are not supported on GbE ports and
configured F_Port trunks. Use the -i option without a port index argument to display the
portSwap status, or alternately use portSwapShow.
-x [hex1 [-hex2]]
Specifies a port or a range of ports identified by port numbers, index number in
hexadecimal format. You may specify multiple port ranges separated by a space, for
example, -x 21-26 28-3c.
-pid pid
Specifies the diagnostics information of a remote switch port along with its peer port.