Reference Guide

836 Brocade Fabric OS Command Reference
53-1004112-02
portShow
FEC Uncorrected Blocks: 0
PEER PORT
portWwn: 20:20:00:27:f8:81:85:69
nodeWwn: 20:20:00:27:f8:81:85:69
PN_PORT Phy Type: PN Port/PF Port [PN Port/PF Port, lossless Ethernet MAC]
Link_failure: 0 Loss_of_sync: 0 Loss_of_sig: 0
Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0
FEC Corrected Blocks: 0
FEC Uncorrected Blocks: 0
To display the information of a remote switch port:
switch:admin> portshow -pid 0x010500
SWITCH PORT0xDDAA00
portWwn: 20:20:00:27:f8:81:85:69
nodeWwn: 20:20:00:27:f8:81:85:69
PN_PORT Phy Type: PN Port/PF Port
Link_failure: 0 Loss_of_sync: 0 Loss_of_sig: 0
Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0
PEER PORT 0xDDAAxx
portWwn: 20:20:00:27:f8:81:85:69
nodeWwn: 20:20:00:27:f8:81:85:69
PN_PORT Phy Type: PN Port/PF Port
Link_failure: 0 Loss_of_sync: 0 Loss_of_sig: 0
Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0
Function Display IP Interface configurations on the Brocade 7840, SX6, or FX8-24 platforms
Synopsis portshow option [slot/]ge_port [optional_args] [--filter filter_args]