Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power
Specifications in the 8510-8 Backbone Hardware Reference Manual)
Configured
Number of
Ports
Blades
Type of
Blade
DCX 8510-8
@110 VAC
(Redundant
configurations)
DCX 8510-8
@200-240 VAC
(Redundant
configurations)
Comments
384 8Gb ports +
QSFP ICLs
FC8-48E Port Blade 4 Power Supplies 4 Power
Supplies
200-240 VAC:
For DCX 8510-8, four
(2+2)
1
220 VAC
Power Supplies are
required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs
FC16-32,
FC16-48, FC8-64,
FC8-32E,
FC8-48E,
FS8-18,FX8-24
Intelligent
Blade /
Combination
Dependent on
configuration.
Requires power
calculation for
specific
configuration
2 or 4 Power
Supplies,
depending on
configuration
For DCX 8510-8, four
(2+2)
1
220 VAC
Power Supplies are
required when any
special purpose
blade are installed
512 16Gb ports FC16-64 Port Blade 4 Power Supplies 2 Power
Supplies
200-240 VAC: 1+1
Power Supplies
110 VAC: 2+2
1
Power
Supplies
512 16Gb ports +
QSFP ICLs
FC16-64 Port Blade 4 Power Supplies 2 Power
Supplies
200-240 VAC: 1+1
Power Supplies
110 VAC: 2+2
1
Power Supplies
Table
Table Table
Table 4
44
4
Power Supply Requirements for DCX
Power Supply Requirements for DCXPower Supply Requirements for DCX
Power Supply Requirements for DCX
8510
85108510
8510-
--
-8
88