Users Guide

188 Fabric OS Message Reference
53-1002929-01
BM-1004
5
Recommended
Action
Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.
BM-1004
Message Blade firmware <Blade firmware> on slot <Slot> is not consistent with system
firmware <System firmware>. Auto-leveling blade firmware to match system firmware.
Message Type LOG
Severity INFO
Probable Cause Indicates that the policy of the specified blade is to auto-level the blade firmware to the system firmware.
This may be due to one of the following reasons:
Blade firmware was detected to be different from the control processor (CP) firmware due to a
firmware upgrade.
The blade was recently inserted and had a different version of the firmware loaded.
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
BM-1005
Message Firmwaredownload timed-out for blade in slot <Slot>. Faulting blade.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the firmwareDownload command failed for the blade in the specified slot.
Recommended
Action
Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.
BM-1006
Message Blade is not configured. Persistently disabling all ports for blade in slot <Slot
number>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the policy of the specified blade is set to persistently disable all ports the first time the blade
is detected. The message indicates either of the following:
The blade was detected in this slot for the first time.
The blade was configured under a different mode.