Users Guide

Fabric OS Message Reference 25
53-1002929-01
Reading the system messages
1
The following is a sample Audit event message.
0 AUDIT, 2005/12/10-09:54:03, [SEC-1000], WARNING, SECURITY,
JohnSmith/root/192.0.2.2/Telnet/CLI, Domain A/JohnsSwitch, , Incorrect password
during login attempt.
The fields in the error message are described in Table 5.
TABLE 5 Audit message field description
Variable name Description
Sequence Number The error message position in the log.
Audit flag Identifies the message as an Audit message.
Time Stamp The system time (UTC) when the message was generated on the switch. The
RASLog subsystem will support an internationalized time stamp format
based on the “LOCAL” setting.
Event ID The message module and number. These values uniquely identify each
message in the Fabric OS and reference the cause and actions
recommended in this manual. Note that not all message numbers are used;
there can be gaps in the numeric message sequence.
Severity The severity of the error, which can be one of the following:
1 – CRITICAL
2 – ERROR
3 – WARNING
4 – INFO
Event Class The event class, which can be one of the following:
CFG
CLI
FABRIC
FIRMWARE
FW
LS
MAPS
RAS
SECURITY
ZONE
User ID The user ID.
Role The role of the user ID.
IP address The IP address.
Interface The interface being used.
Application Name The application name being used on the interface.
Admin Domain The Admin Domain, if there is one.
Switch name The defined switch name or the chassis name of the switch depending on
the action; for example, HA messages typically show the chassis name and
login failures show the logical switch name.
This value is truncated if it is over 16 characters in length.
Execute the chassisName command to name the chassis or the switchName
command to rename the logical switch.