566 Fabric OS Message Reference
53-1002929-01
HIL-1311
5
Recommended
Action
Because the fans are not field-replaceable, replace the switch if the temperature is high.
HIL-1311
Message No fans are faulty.
Message Type LOG
Severity INFO
Probable Cause Indicates recovery from an earlier condition of one or more fans having failed.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
HIL-1401
Message One fan FRU missing. Install fan FRU immediately.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a fan field-replaceable unit (FRU) has been removed.
Recommended
Action
Install the missing fan FRU.
HIL-1402
Message Two fan FRUs missing. Install fan FRUs immediately.
Message Type LOG
Severity WARNING
Probable Cause Indicates that two fan field-replaceable units (FRUs) have been removed.
Recommended
Action
Install the missing fan FRUs immediately.