Users Guide

Fabric OS Message Reference 673
53-1002929-01
PLAT-1003
5
PLAT-1003
Message <Info message> Slot <Blade Slot number> C/BE: 0x<Captured Command/Byte-Enables
data> ADBUS: 0x<Captured AD bus data> misc_intr 0x<Bridge reset interrupts>.
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that peripheral component interconnect (PCI) bus hang was detected.
Recommended
Action
Replace the field-replaceable unit (FRU).
PLAT-1004
Message Switch has older FPGA rev 0x<FPGA version already installed in HW>. Upgrade to
newer rev 0x<FPGA version which Fabric OS carries> using the fpga_update command.
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that Fabric OS has older field-programmable gate array (FPGA) version. This message is
applicable only to Brocade 5470.
Recommended
Action
Upgrade FPGA to new version.
PLAT-1005
Message Incompatible midplane detected. All internal ports will be disabled.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the chassis has the revision 1.0 midplane.
This message occurs only on the Brocade M6505 switch.
Recommended
Action
Replace the midplane with a revision 1.1 midplane.