Users Guide

Fabric OS Message Reference 725
53-1002929-01
SEC-1059
5
SEC-1059
Message Fail to <operation, e.g., save, delete, etc.,> <named item> to flash.
Message Type LOG
Severity ERROR
Probable Cause Indicates the operation failed when writing to flash memory.
Recommended
Action
Run the supportFtp - e command to FTP files from the switch and remove them from the flash memory.
SEC-1062
Message Invalid number of Domains in Domain List.
Message Type LOG
Severity ERROR
Probable Cause Indicates that either no domains or domains more than the maximum number supported are specified.
Recommended
Action
Enter the correct number of domains.
SEC-1063
Message Failed to reset statistics.
Message Type LOG
Severity ERROR
Probable Cause Indicates that either the type or the domains specified are invalid.
Recommended
Action
Enter valid input.
SEC-1064
Message Failed to sign message.
Message Type LOG
Severity ERROR
Probable Cause Indicates the public key infrastructure (PKI) objects on the switch are not in a valid state and the
signature operation failed.