Users Guide

892 Fabric OS Message Reference
53-1002929-01
UCST-1003
5
UCST Messages
UCST-1003
Message Duplicate Path to Domain <domain ID>, Output Port = <port number>, PDB pointer =
0x<value>.
Message Type LOG
Severity INFO
Probable Cause Indicates that duplicate paths were reported to the specified domain from the specified output port. The
PDB pointer value displayed in the message is the address of the path database and provides debugging
information.
Recommended
Action
No action is required.
UCST-1007
Message Inconsistent route detected: Port = <port number>, should be <port number>.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the switch detected an inconsistency in the routing database between the routing protocol
and the hardware configuration. The first port number displayed is what the hardware has configured and
the second port number displayed is what the protocol is using.
Recommended
Action
Run the switchDisable command and then the switchEnable command to reset the routing database.
Run the uRouteShow command to display the new routing tables.
UCST-1020
Message Static route (input-area: <port number>, domain: <domain ID> output-area: <port
number>) has been ignored due to platform limitation.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the configured static route cannot be applied to the routing database because of a platform
limitation.
Recommended
Action
No action is required.