Deployment Guide

Fabric OS Message Reference 147
53-1003140-01
AN-1001
5
AN Messages
AN-1001
Message Failed to allocate memory: (<function name>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the switch.
AN-1002
Message Failed to initialize; rc = <error>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the initialization of the "trafd" daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command.
AN-1003
Message Latency bottleneck on port <slot number>/<port number within slot number>.
<percentage of seconds affected by latency bottlenecking> pct. of <observation
period over which the percentage of affected seconds is reported> secs. affected.
Avg. delay <observed average time between frames during affected seconds> us. Avg.
slowdown <observed throughput drop factor during affected seconds>.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause For an F_Port, indicates that the attached device is slow in responding to frames going out of the
specified port. This latency may be inherent in the device or due to heavy workload on the device.
For a long-distance E_Port, may indicate too few credits for the distance. For a non-long-distance
E_Port, indicates latency produced by a device downstream of the E_Port and is an indication of
back-pressure produced by that latency.