Deployment Guide

Fabric OS Message Reference 149
53-1003140-01
AN-1010
5
AN-1010
Message Severe latency bottleneck detected at slot <slot number> port <port number within
slot number>.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause Indicates credit loss at the specified port, a downstream port, or a very high latency device at the edge of
the fabric.
Recommended
Action
Contact your switch service provider for assistance.
AN-1011
Message Could not distinguish between primary and dependent severe latency bottleneck on
slot <slot number> port <port number within slot number> because port mirroring is
enabled on this port.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause Indicates that resources that are needed to determine whether there is complete credit loss on a virtual
channel (VC) at the specified port are used by port mirroring.
Recommended
Action
Contact your switch service provider for assistance.
AN-1012
Message Credits did not return from other end. Complete loss of credits on a VC on slot
<slot number> port <port number within slot number>.
Message Type LOG | AUDIT
Class FABRIC
Severity WARNING
Probable Cause Indicates a credit loss.
Recommended
Action
If this message is not followed by the AN-1013 message, contact your switch service provider for
assistance.