Deployment Guide

Fabric OS Message Reference 317
53-1003140-01
EM-1073
5
EM-1073
Message Blade devices cannot be accessed. The blade in slot <FRU slot number> is being
moved to ABSENT state.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the devices on the blade were not accessible. Blade is being tranisitioned to the ABSENT
state.
Recommended
Action
Reseat or replace the affected blade.
EM-1134
Message <FRU Id> set to faulty, rc=<return code>.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.
Recommended
Action
Reseat the FRU.
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem persists, replace the FRU.
EM-2003
Message <Slot Id or Switch for pizza boxes> has failed the POST tests. FRU is being
faulted.
Message Type LOG
Severity ERROR
Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the
/tmp/post[1/2].slot#.log file for more information on the faults. To view this log file, you must be logged in
at the root level. The ID will be Switch for non-bladed systems.
Recommended
Action
On bladed systems, reseat the specified FRU.
On non-bladed switches, restart or power cycle the switch.
If the problem persists, perform the following actions: