FABR-1054
5
FABR-1054
Message Rebooting the standby as it received an update before port [<Port Number>] is
expanded.
Message Type LOG | FFDC
Severity INFO
Probable Cause Indicates that the standby control processor (CP) did not have the port because the port expand
operation is still in progress and the standby CP has received a port update. The standby CP reboots
automatically to ensure sync and attain the normal state. This is a rare occurrence.
Recommended
Action
No action is required.
FABR-1055
Message F_Port trunking cannot be enabled on the slot <Slot Number> port <Port Number> due
to inconsistent port configuration.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified F_Port is unable to join its assigned trunk area group because of mismatch in
the port configuration with the other trunk area members.
Recommended
Action
Check the configuration of the port with all other ports intended to be part of the same trunk group. Use
the porttrunkarea --show to identify the trunk members of the specified F_Port and the portcfgshow