Deployment Guide

Fabric OS Message Reference 591
53-1003140-01
HIL-1101
5
HIL Messages
HIL-1101
Message Slot <slot number> faulted, <nominal voltage> (<measured voltage>) is above
threshold.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the blade voltage is above threshold.
Recommended
Action
Replace the faulty blade or switch (for non-bladed switches).
HIL-1102
Message Slot <slot number> faulted, <nominal voltage> (<measured voltage>) is below
threshold.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the blade voltage is below threshold.
Recommended
Action
Replace the faulty blade or switch (for non-bladed switches).
HIL-1103
Message Blower <blower number> faulted, <nominal voltage> (<measured voltage>) is above
threshold.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the fan voltage is above threshold.
Recommended
Action
Run the psShow command to verify the power supply status.
Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are
seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.