Deployment Guide

718 Fabric OS Message Reference
53-1003140-01
PORT-1005
5
PORT-1005
Message Slot <slot number> port <port on slot> does not support configured L_Port. Issue
portCfgLport to clear configuration.
Message Type LOG
Severity WARNING
Probable Cause Indicates the specified port is configured to be an L_Port, but the port does not support L_Port. If an
L_Port is connected, then the port will be disabled because the port does not support L_Port. If an
E_Port or F_Port is connected, then the port will not come up because it is configured to be an L_Port.
Recommended
Action
Execute the portCfgLport command to clear the L_Port configuration.
PORT-1006
Message Configuration changed for port (ID: <port number>) in No_Module or No_Light state.
Message Type AUDIT | LOG
Class CFG
Severity INFO
Probable Cause Indicates the configuration changes were made to an offline port in the No_Module or No_Light state.
Recommended
Action
No action is required.
PORT-1007
Message Port (ID: <port number>) has been renamed to (<port name>).
Message Type AUDIT | LOG
Class CFG
Severity INFO
Probable Cause Indicates a port has been reconfigured with a different name.
Recommended
Action
No action is required.