Deployment Guide

964 Fabric OS Message Reference
53-1003140-01
ZONE-1002
5
ZONE Messages
ZONE-1002
Message WWN zoneTypeCheck or zoneGroupCheck warning(<warning string>) at port(<port
number>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that a zone filter or zone group check failure occurred. The frame filter logic reported a failure
when creating or adding the zone groups during port login (PLOGI) trap processing. This message
usually indicates problems when adding the content-addressable memory (CAM) entries before the filter
setup.
Recommended
Action
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
ZONE-1003
Message zone(<current zone>) contains (<domain id>, <port number>) which does not exist.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the port zone member that is targeted for the local switch contains a nonexistent port. The
specified port number in the effective zoning configuration (displayed in the error message) is out of
range.
Recommended
Action
Edit the zone database and change the port number to a viable value in the effective configuration.
ZONE-1004
Message Base PID: 0x<Base PID>, Port Index: <Port Index>, Port: <Slot/Port>: enforcement
changed to Session-based HARD Zoning.
Message Type LOG
Severity INFO
Probable Cause Indicates that the zoning enforcement has changed to session-based hard zoning due to one of the
following conditions:
The zone has a mix of WWN and domain,index (D,I) members.
The Source Identifier (S_ID) list of the hardware-enforced zoning exceeded the S_ID limit.