C3-1018
5
C3-1018
Message Link reset threshold value exceeded in the link S<slot number>,P<port
number>(<blade port number>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified blade is faulted because the link reset threshold value has exceeded.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
C3-1019
Message S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.
Recommended
Action
Restart the system at the next maintenance window.
C3-1020
Message S<slot number>,P<port number>(<blade port number>): Some non-critical CRC with
good EOF errors were observed: current:0x<last_crc_good_eof_cnt>,
last:0x<total_crc_good_eof_cnt> thresh1:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that some non-critical errors were detected in the hardware.
Recommended
Action
No action is required.