Messages Reference Guide

332 Fabric OS Message Reference
53-1002749-01
FCOE-1019
5
Recommended
Action
Disable the active FCoE session on VLAN using the no fcoe command and try adding the FCMAP
again.
FCOE-1019
Message FLOGI ignored as FCMAP is not configured on FCoE VLAN.
Message Type LOG
Severity WARNING
Probable Cause Indicates that FCMAP has not been configured on FCoE VLAN.
Recommended
Action
Configure FCMAP on the FCoE VLAN using the fcoe --fcmapset command.
FCOE-1021
Message Port is already logged in.
Message Type LOG
Severity INFO
Probable Cause Indicates that the N_Port device has already logged in or is in the process; duplicate FLOGI received.
Recommended
Action
No action is required.
FCOE-1022
Message Max FCoE device login limit reached.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch has reached its maximum allowed FCoE device limit.
Recommended
Action
Do not add any more FCoE devices to the switch.