Messages Reference Guide

450 Fabric OS Message Reference
53-1002749-01
FW-1115
5
FW-1115
Message <Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the number of times E_Ports have gone down has risen above the high boundary. E_Ports
go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause
E_Ports to go down. Down E_Port may be caused by transient errors.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. Check both ends of the physical connection and verify that the SFP functions properly.
FW-1116
Message <Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the number of times E_Ports have gone down has changed from a value outside of the
acceptable range to a value within the acceptable range. E_Ports go down each time you remove a cable
or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down. Down E_Port may be
caused by transient errors.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1117
Message <Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the number of fabric reconfigurations has changed. The following occurrences can cause a
fabric reconfiguration:
Two switches with the same domain ID have connected to one another.
Two fabrics have joined.
An E_Port has gone offline.
A principal link has segmented from the fabric.