Release Notes

Open Defects in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 51 of 93
Defect ID:
DEFECT000461016
Technical Severity:
Medium
Summary:
When moving Xge ports between Logical Switches the Xge ports will not enable after a portenable in
the new Logical Switch.
Symptom:
After moving an enabled XGE port from LS to a different LS, the XGE port remains disabled after
port enable in the new switch.
Workaround:
Either issue the portdisable command for the xge port before moving the port to a different LS or
once you have moved the ports to the different LS issue a switch disable/switch enable sequence to
enable the xge port.
Feature:
Striker/Spike Platform Services
Function:
Spike Platform Module
Reported In Release:
FOS7.2.0
Probability:
Low
Defect ID:
DEFECT000461162
Technical Severity:
Medium
Summary:
The thconfig command cannot set high threshold and low threshold in one command line
Symptom:
Executing “thconfig” command to set high threshold and low threshold in one command line outputs:
“Internal API failed..."
Feature:
FOS Software
Function:
Fabric Services
Service Request ID:
1172423
Reported In Release:
FOS7.0.2
Probability:
High
Defect ID:
DEFECT000462242
Technical Severity:
Medium
Summary:
Inconsistent enforcement of RBAC permissions for config commands run in interactive mode and in
non-interactive mode
Symptom:
For Chassis and LF user role as "user", config commands(configshow/configdownload/configupload)
trigger "RBAC permission denied." in interactive mode where as it works in non-interactive mode
Feature:
FOS Software
Function:
Fabric Services
Service Request ID:
1171446
Reported In Release:
FOS6.3.2
Probability:
High
Defect ID:
DEFECT000463170
Technical Severity:
Medium
Summary:
ipsecconfig command may hang the command line
Symptom:
ipsecconfig --disable command may hang and not work properly. Subsequent disable/re-enables may
fail.
Feature:
FOS Security
Function:
Other
Reported In Release:
FOS7.2.0
Probability:
Medium
Defect ID:
DEFECT000463913
Technical Severity:
Medium
Summary:
Kernel panic occurs when running multiple supportShow commands in several logical switches
Symptom:
The switch experienced a kernel panic after running the supportShow command on multiple logical
switches simultaneously on the switch.
Workaround:
Avoid running multiple supportshow from the different sessions.
Feature:
FOS Software
Function:
Panic / OOM
Service Request ID:
1187706
Reported In Release:
FOS7.1.0
Probability:
Low
Defect ID:
DEFECT000464450
Technical Severity:
Medium
Summary:
"sleep:invalid Chassis Role" message is displayed while running supportsave under user role
Symptom:
The supportsave comman completes successfully even though "sleep:invalid Chassis Role" message is
displayed in the output.
Feature:
RAS
Function:
FFDC/Supportsave
Reported In Release:
FOS7.2.0
Probability:
Medium