Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 61 of 93
Defect ID:
DEFECT000422596
Technical Severity:
Medium
Summary:
sw.mib syntax error.
Symptom:
sw.mib fails to load in management application
Workaround:
Manually edit the SW.mib file
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS7.0.0
Service Request ID:
1093174
Defect ID:
DEFECT000423875
Technical Severity:
Medium
Summary:
Race condition during SNMP query of interface statistics caused BR8000 switch to panic.
Symptom:
B8000 switch experienced "nsmd" daemon panic and subsequent switch reboot
Risk of Fix:
Low
Probability:
Low
Feature:
CEE-Protocol
Function:
NSM
Reported In Release:
FOS6.4.2
Service Request ID:
1094688,1143458
Defect ID:
DEFECT000425002
Technical Severity:
High
Summary:
LDAP authentication stops working after the "cleanup" command is run under root.
Symptom:
ldap authentication stops working after running "cleanup" command under root account.
Workaround:
Manually create the softlink
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
OS: Configuration
Reported In Release:
FOS6.4.2
Service Request ID:
1088751
Defect ID:
DEFECT000425570
Technical Severity:
Medium
Summary:
FabricWatch trap 5 is not sent to 3rd party tool in FOS v7.0.1
Symptom:
Customer is unable to capture fabric watch trap(Specific-trap: 5) using 3rd party tool with FOS
v7.0.1, but FOS v6.4.2x was able to capture. Raslog and email communication are able to receive
these traps.
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS7.0.1
Service Request ID:
1098326,1122983,1200
Defect ID:
DEFECT000426616
Technical Severity:
Medium
Summary:
fwfrucfg in BR6505 does not show list to configure FRUs other than SFP
Symptom:
Customer cannot use fwfrucfg cmd to configure FRUs other than SFP on BR6505.
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS7.0.2
Service Request ID:
1100552
Defect ID:
DEFECT000426900
Technical Severity:
Medium
Summary:
switchbeacon and chassisbeacon should not be allowed to be turned on at the same time via Web
Tools.
Symptom:
Nonsensical led behavior will be exhibited on the switch.
Risk of Fix:
Medium
Probability:
Low
Feature:
Mgmt Embedded - HTTP
Function:
Other
Reported In Release:
FOS7.1.0