Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 71 of 93
Defect ID:
DEFECT000437958
Technical Severity:
Medium
Summary:
Remove excessive internal I2C reset raslog message
Symptom:
i2c reset message on recoverable errors causing unnecessary concerns
Risk of Fix:
Low
Probability:
Low
Feature:
8G Platform Services
Function:
Other
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000438017
Technical Severity:
Medium
Summary:
SNMP configuration replication overwrites AAA LDAP Settings.
Symptom:
When trying to replicate SNMP settings alone from one switch to another switch using BNA, CLI,
AAA settings also getting replaced.
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
OS: Configuration
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000438165
Technical Severity:
High
Summary:
Unable to vary devices online when FICON XRC Emulation is disabled but FICON Tape Emulation
is enabled.
Symptom:
Device cannot come online with error messages: "UNABLE TO ESTABLISH DYNAMIC PATHING
FOR THIS DEVICE"
Workaround:
Disable FCIP Tape Pipelining
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS6.4.1
Service Request ID:
1129930
Defect ID:
DEFECT000438388
Technical Severity:
High
Summary:
XTUN-1007 errors logged during systemverification tests on a DCX/8510 when FX8-24 blade is
installed
Symptom:
Message [XTUN-1007], 2114714, SLOT 6 | CHASSIS, ERROR, Brocade_DCX, FCIP FC frame
drop due to truncated receive on slot=1 DP=2 BLS=0 DR=0 Frames Dropped=1068703 appears
numerous times
Risk of Fix:
Low
Probability:
Low
Feature:
FCIP
Function:
FCIP Port
Reported In Release:
FOS7.1.0
Service Request ID:
1131027
Defect ID:
DEFECT000438768
Technical Severity:
High
Summary:
FCR device data imported in Routed Fabric but Name Server is missing all imported PIDs
Symptom:
Devices may be imported and exist in FCR but they do not exist in the name server. The
portcamshow command will not show a given storage port connected to the switch in this scenario.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
1125000,1205419
Defect ID:
DEFECT000438901
Technical Severity:
High
Summary:
kernel panic while running portcfgspeed command on internal port of an embedded switch.
Symptom:
BR5470 embedded switch panic'd while running portcfgspeed command, causing momentary outage.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS6.4.2
Service Request ID:
1132056