Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 74 of 93
Defect ID:
DEFECT000441818
Technical Severity:
Medium
Summary:
For 16GB fixed port count switches and port blades, the number of ports displayed by portledtest are
not matching the number of physical front end facing FC ports
Symptom:
The overall functionality of portledtest is not affected however, portledtest displays results for internal
as well as front facing ports.
Risk of Fix:
Low
Probability:
Medium
Feature:
Diagnostics
Function:
Other
Reported In Release:
FOS7.1.0
Service Request ID:
1136285
Defect ID:
DEFECT000441913
Technical Severity:
High
Summary:
A 16Gbit switch may panic when an ICL port enters soft fault state. This is very unlikely but may
also occur with Backend Internal or Backend External port.
Symptom:
During switch install, slot power cycle test, observed 16G switch panic.
Risk of Fix:
Low
Probability:
Medium
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS7.0.2
Service Request ID:
1032557
Defect ID:
DEFECT000442070
Technical Severity:
Medium
Summary:
When transfering a CSR using IPv6, the status message says failed when it actually succeeded.
Symptom:
After a successful transfer of a CSR, the switch reports "Failed to export CSR to remote host:".
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
Security
Reported In Release:
FOS7.0.2
Service Request ID:
1137829
Defect ID:
DEFECT000442080
Technical Severity:
Medium
Summary:
Making auto-tuned value persistent across reboot
Symptom:
Values from serds auto/manual tuning session are lost after poweroff/on blade or cold reboot of
switch.
Risk of Fix:
Low
Probability:
Low
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Reported In Release:
FOS7.0.2
Defect ID:
DEFECT000442112
Technical Severity:
High
Summary:
With OSTP enabled, 3rd party device write errors are encountered during backup processing
Symptom:
3rd party device write errors during backup processing similar to:
mm/dd/yy hh:mm:ss An I/O error occurred while accessing drive xxx (/dev/rmtyy) for WRITE
operation, errno = 78, rc = 1.
Workaround:
Disable FCIP Open Systems Tape Pipelining
Risk of Fix:
Low
Probability:
Medium
Feature:
FCIP
Function:
Emulation
Reported In Release:
FOS7.0.0
Service Request ID:
1132526
Defect ID:
DEFECT000442422
Technical Severity:
High
Summary:
System security card is not being read on BES/FS8-18 card readers.
Symptom:
Authentication for crypto operations on BES/FS8-18 fails. In this case, BES/FS8-18 functions as an
ordinary FC switch or blade when it is powered up, but use of the encryption engine is denied as a
result.
Workaround:
Disable the systemcard feature, issue cryptocfg -- set -systemcard disable from the encryption
group leader.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS-Infrastructure
Function:
Other
Reported In Release:
FOS7.1.0