Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 79 of 93
Defect ID:
DEFECT000448752
Technical Severity:
Medium
Summary:
Web Tools does not show Standby CP firmware level
Symptom:
Web Tools "Switch Admin | Fware Download panel" shows "none" for Standby CP level
Risk of Fix:
Low
Probability:
High
Feature:
WebMgmt
Function:
Firmware Download
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000448802
Technical Severity:
High
Summary:
Discrepancy between Recommended Action on C2-1012 Error Message from Fabric OS Message
Reference and BNA 12.0 Master Log
Symptom:
Discrepancy between Recommended Action on C2-1012 Error Message from Fabric OS Message
Reference and BNA 12.0 Master Log
Workaround:
Power Cycle and Turn on Backend Credit Recovery
Risk of Fix:
Medium
Probability:
Medium
Feature:
Message Reference
Function:
Edit/Correct
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000448983
Technical Severity:
High
Summary:
FICON DASD CHPID activation fails through FCIP emulating tunnel.
Symptom:
CHPID activation fails
Workaround:
Disable FCIP and all FICON emulation on a tunnel
Risk of Fix:
Low
Probability:
High
Feature:
FCIP
Function:
Emulation
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000450420
Technical Severity:
Medium
Summary:
When multiple priorities are run with TPERF with low rate, TPERF timeout.
Symptom:
Tperf terminates when running with all three ( -high -medium -low) QOS setting and low bandwidth
under 70 Megabits
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS7.0.2
Service Request ID:
1154244
Defect ID:
DEFECT000450480
Technical Severity:
High
Summary:
Firmware downgrade from v7.1.0 to v7.0.0d is erroneously blocked (Error: FMS + Allow XISL
configured) when "Allow XISL" is not enabled on logical switch.
Symptom:
Firmwaredownload is erroneously blocked.
Risk of Fix:
Low
Probability:
Low
Feature:
Mgmt Embedded - CAL
Function:
VF
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000451033
Technical Severity:
High
Summary:
Supportsave fails using Webtools with error message "Invalid Pathname"
Symptom:
Using Webtools to take a supportsave will result in an error message "Invalid Pathname." if the
default pathname that Webtools puts into the dialog box is used. If a directory is created, and that
name is put in the dialog box, Webtools will hang.
Risk of Fix:
Low
Probability:
High
Feature:
WebMgmt
Function:
WT Platform Support
Reported In Release:
FOS7.1.0