Release Notes

Closed defects without code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 90 of 93
Defect ID:
DEFECT000462978
Technical Severity:
High
Summary:
FS8-18 failure on an 8510 chassis
Symptom:
FS8-18 may fault with reason code 21 while coming up.
Workaround:
Reseat or powercycle the FS8-18 blade.
Reason Code:
Can Not Fix
Probability:
Medium
Feature:
Data Security
Function:
Platform
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000463914
Technical Severity:
High
Summary:
nodes fenced, unable to find data on encrypted LUNs
Symptom:
Corrupted LUNs causing nodes to be fenced.
Reason Code:
Not a Defect
Probability:
High
Feature:
Data Security
Function:
Disk Encryption
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000244193
Technical Severity:
Medium
Summary:
FRU status change trap with status off is not generated on inserting a fan, blade or WWN card but
does get generated for a power supply insertion.
Symptom:
FRU status change is not correctly updated.
Reason Code:
Already Fixed in Release
Probability:
Low
Feature:
Mgmt Embedded - SNMP
Function:
Other
Reported In Release:
FOS6.2.0
Defect ID:
DEFECT000336430
Technical Severity:
Medium
Summary:
Web Tools display in Switch Admin shows trunking bandwidth of 32 Gbps when trunk is actually 16
Gbps as shown in CLI
Symptom:
Inaccurate Web Tools display for trunking bandwidth.
Reason Code:
Not a Defect
Probability:
Medium
Feature:
Mgmt Embedded - CAL
Function:
Other
Reported In Release:
FOS6.4.0
Defect ID:
DEFECT000370589
Technical Severity:
Medium
Summary:
Attempts to persistently enable persistently disabled ports through Brocade Network Advisor fail
Symptom:
Ports remain persistently disabled in the logical switches dialog
Reason Code:
Not Reproducible
Probability:
Low
Feature:
16G Platform Services
Function:
Other
Reported In Release:
FOS7.0.0
Defect ID:
DEFECT000414198
Technical Severity:
Medium
Summary:
F port on core ag in cascaded configuration comes up as E-port (unknown) after configdownload
Symptom:
F port on core ag in cascaded configuration comes up as E-port (unknown)
Workaround:
Toggle the ports on which the issue is observed
Reason Code:
Not a Defect
Probability:
Medium
Feature:
Access Gateway Services
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000420051
Technical Severity:
Medium
Summary:
On DCX with FC8-48 in slot 3, CRC with good EOF errors are seen.
Symptom:
CRC with good EOF observed on DCX with FC8-48 in slot 3 on ports 3/42 <-> 8/139
Reason Code:
Already Fixed in Release
Probability:
Medium
Feature:
FOS Software
Function:
System Performance
Reported In Release:
FOS6.4.3
Service Request ID:
1035482