Troubleshooting and Diagnostics Guide

Fabric OS Troubleshooting and Diagnostics Guide 21
53-1002751-01
FC-FC routing connectivity
2
switch:admin> pathinfo 5
Hop In Port Domain ID (Name) Out Port BW Cost
-----------------------------------------------------------------------------
0 2 1 (sw0) 6 4G 500
1 23 2 (sw0) 8 4G 500
2 4 3 (sw0) 3 4G 500
3 12 4 (sw0) 18 4G 10000
4 4 7 (switch_3) 0 4G 500
5 26 5 (switch_3) E - -
To display basic and extended statistics in interactive mode:
switch:admin> pathinfo
Max hops: (1..127) [25]
Fabric Id: (1..128) [-1]
Domain|Wwn|Name: [] 8
Source port: (0..15) [-1]
Destination port: (0..255) [-1]
Source pid: (0x0..0xefff00) [ffffffff] 0x061600
Desination pid: (0x0..0xefff00) [0] 0x01f001
Basic stats (yes, y, no, n): [no] y
Extended stats (yes, y, no, n): [no] y
Trace reverse path (yes, y, no, n): [no]
Source route (yes, y, no, n): [no]
Timeout: (1000..30000) [10000]
Target port is Embedded
Hop In Port Domain ID (Name) Out Port BW Cost
-----------------------------------------------------------------------------
0 2 1 (sw0) 6 4G 500
1 23 2 (sw0) 8 4G 500
2 4 3 (sw0) 3 4G 500
3 2 4 (sw0) 24 4G 10000
4 3 7 (switch_3) 2 4G 500
5 27 5 (switch_3) 24 - -
Reverse path
6 24 5 (switch_3) 27 4G 500
7 2 7 (switch_3) 3 4G 500
8 24 4 (sw0) 2 4G 500
9 3 3 (sw0) 4 4G 10000
10 8 2 (sw0) 23 4G 500
11 6 1 (sw0) 2 - -
(output truncated)
For details about the pathInfo command, refer to the Fabric OS Command Reference.
Performance issues
Symptom General slow-down in FCR performance and scalability.
Probable cause and recommended action
As LSAN zone databases get bigger, it takes more switch resources to process them. Use the
enforce tag feature to prevent a backbone switch from accepting unwanted LSAN zone databases
into its local database.