Release Notes

Closed with Code Change in Fabric OS v7.2.1e
Fabric OS v7.2.1e Release Notes v1.0 Page 36 of 82
Defect ID:
DEFECT000540585
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.2.1
Technology Area:
supportShow
Symptom:
Support Save output does not include VE or GE port information
Condition:
This is seen after multiple logical switches have been created and one or more of the logical switches
have been deleted and the VE ports reside in a logical switch that was created after one that was
deleted.
Workaround:
Recreate empty logical switches up to the limit of logical switches in that chassis.
Defect ID:
DEFECT000540694
Technical Severity:
Medium
Probability:
High
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.2.1
Technology Area:
Top Talker Monitors
Symptom:
Switch repeatedly logs the following raslog message:
"[PS-1009], 16386, SLOT 7 | FID 128, WARNING, , Failed to add the device updates in condb
database."
This can mislead the customer on the number of
devices supported by name server, zoning and device
connectivity.
Condition:
This happens when there are large number of devices zoned together and with "Performance Monitor
license".
There is no impact to device connectivity, but Top talkers may not be able to display the top talking
flows
Defect ID:
DEFECT000541661
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.2.1
Technology Area:
Virtual Fabrics
Symptom:
Active CP Panic may occur while running Brocade SAN Health report.
Condition:
This may be encountered in a large virtual fabric environment when running back to back CLI
commands "lfcfg --showall -xxxx"
Defect ID:
DEFECT000542388
Technical Severity:
High
Probability:
High
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.1.1
Technology Area:
Access Gateway
Symptom:
Even though there are no mappings being shown in ag -mapshow for some ports, available F-ports
cannot be mapped to existing N-ports.
All F-ports are reported to be mapped to an non-existent N-port, and do not show up in ag -mapshow.
Condition:
Inconsistent config file is downloaded to the switch with configdownload.
The inconsistency entails one of the following:
- F-to-N-port mapping for F-Ports, or
- No port config, but F-to-N-port mapping exists.
Recovery:
Configure all non-used ports (ports that are not N-port and not F-port) as N-port and then remove that
configuration. In rare cases, even the F-ports may need to be temporarily configured as N-ports and
then remove the configuration.
Defect ID:
DEFECT000542559
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.4.0
Technology Area:
FCIP
Symptom:
Tunnel bounce with an associated BLS-5024 FFDC event.
Condition:
This issue can occur after FCIP tunnel bounces due to WAN outage or other network issue.