Users Guide

66 Fabric Watch Administrator’s Guide
53-1002998-01
Recommended port configuration settings
7
TABLE 22 Recommended configuration for the Port class
E=Error_Log, S=SNMP_Trap,
P=Port_LOG_LOCK,
M=EMAIL_ALERT, pf=Port Fence
Trait Configuration
Class
Area
Default
Custom
Unit
Time Base
Low Thresh
High Thresh
Buffer
Default
Custom
Below
Above
Notes
Port Link Loss X Errors Minute 0 500 50 X
Sync Loss X Errors Minute 0 500 50 X
Signal Loss X Errors Minute 0 5 0 X
Protocol Error X Errors Minute 0 5 0 X
Invalid Words X Errors Minute 0 25 0 X E
Invalid CRCs X Errors Minute 0 5 0 X E
RX Performance X Percentage Minute 0 100 0 X
TX Performance X Percentage Minute 0 100 0 X
State Changes X Changes Minute 0 50 0 X
Link Reset X Errors Minute 0 500 50 X
C3 Discard X Errors Minute 0 5 0 X
E_Port Link Loss X Errors Minute 0 0 0 X
Sync Loss X Errors Minute 0 45 0 X E,S
Signal Loss X Errors Minute 0 45 0 X E,S
Protocol Error X Errors Minute 0 5 0 X
Invalid Words X Errors Minute 0 40 0 X E,S,F pf
Invalid CRCs X Errors Minute 0 20 0 X E,S,F pf
RX Performance X Percentage Minute 0 75 0 X E E
TX Performance X Percentage Minute 0 75 0 X E E
State Changes
(E/VE_Port)
XChangesMinute0 500X
Link Reset X Errors Minute 0 500 50 X
Utilization (VE_Port) X Percentage Minute 0 100 0 X
Packet Loss (VE_Port) X Errors Minute 0 10 0 X
C3 Discard X Errors Minute 0 5 0 X E
Trunk Util X Percentage Minute 0 75 0 X E