Administrator Guide

66 Fabric Watch Administrator’s Guide
53-1002752-01
portThConfig command procedures
7
TABLE 18 FOP_Port and FCU_Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Cyclic redundancy
check (CRC)
Monitors the
number of CRC
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Invalid transmission
words (ITW)
Monitors the
number of invalid
words transmitted.
For Fabric OS
versions 7.1.0 and
later, the ITW
counter includes a
physical coding
sublayer (PCS)
violation. ITW
violations can occur
due to an ITW
violation, a PCS
violation, or both.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Class 3 discards
(C3TX_TO)
Class 3 discards
frames due to time
out or destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Link loss Monitors the
number of link
failures.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative
Out_of_range
Signal loss Monitors the
number of signal
loss errors.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Sync loss Monitors the
number of loss of
synchronization
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative
Out_of_range
Protocol errors (PE) Monitors the
number of primitive
sequence errors.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Received packets
(RXP)
Monitors the receive
rate, by percentage.
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Below: 0
Above: 0
Informative
Informative